TESTING HEAT PUMP SYSTEMS IN A LABORATORY

NewsSep • 22 • 2017
art_20171026151200532 COOPER&HUNTER

Finnish magazine TM Rakennusmaailma has taken testing of heat pumps from different manufacturers. For magazine issue, with help from natural resource center freezing warehouse in Vihti town, Finland, they tested equipment, which can operate in winter time, from C&H, Panasonic and Daikin. Heat pumps from these manufacturers, in according to existing data, can operate properly even when it’s -13° F(-25°C) degrees below zero.

The measurement environment

 

 

ManufacturerCooper&HunterDaikinPanasonic
Indoor unitCH-12FTXHV-BFTXZ35NV1BCS-VZ9SKE
Outdoor unitCH-12FTXHV-BRXZ35NV1BCU-VZ9SKE
Dimensions, weight   
Indoor unit (WxHxD) mm860x305x170798x295x372890x295x375
Weight (kg)11,515,014,5
Outdoor unit (WxHxD) mm899x596x378795x693x300799x630x299
Weight (kg)44,550,041,5
Refrigerant / weight (kg)R410/1,30R32/1,34R32/1,20
Compressorrotaryswingrotary
Power   
Heating capacity (kW)3,44,53,6
Energy efficiency class (heating)A+++*)A+++*)A+++*)
COP4,93ei ilm.5,63
SCOP5,1*)5,73*)6,2*)

 

NoiseC&HDaikinPanasonic
dB(A)46,153,050,9

 

 

The measurements were used to study the air-source heat pumps heating power and energy consumption at different outside temperatures when heating the indoor space to 68°F (+20°C).

The magazine has chosen leaders in air flow heat pumps manufacturing, and all equipment has showed a good result in testing and proved the ability to operate at -22°F (-30°C). Heat pump from Cooper&Hunter is a pioneer in the introduction of the air-source heat pump compressor technology. The device of 12-series has a nominal heating capacity of 3.4 KW. It’s equipped with a two-stage compressor that worked during the tests. C&H distinctive feature is radio remote control and also ability to control the device using the WiFi technology. The device worked very consistently and seamlessly at very cold temperatures, with extra low noise level.

C&H heat pump with 2-stage compressor worked very stable from 44.6°F(+7°С) to 19.4°F(-7°С ), but the best results were achieved at 14°F(-10°С) (the most effective operation). Editor’s Choice: CH-12FTXHV-B – the best heat pump in terms of price / quality.

SOURCES:
Kylmaan viritetyt ilmalampopumput